Items |
Standards |
Requirements |
Result |
GreenGuard Gold
Certified |
UL 2818 - 2013 Gold Standard for Chemical Emissions for Building Materials, Finishes and
Furnishings |
Refer to Standards |
Pass |
Floorscore
Certification |
SCS-EC10.3-2014v3.0 |
Refer to Standards |
Pass |
CE Certification |
EN14041 |
Refer to Standards |
Pass |
Fire resistance |
EN 9239-1
EN ISO11925-2
EN 13501-1 |
Critical Fluxf≥8.0kW/m2
Fs≤150mm within 20s
Smoke≤750% minutes |
Bfl-S1 |
Phthalate tests
(DBP/BBP/DEHP/DINP/
DNOP/DIDP) |
EN 14372:2004 |
N/A |
Free |
Dimension stability |
ASTM F2199-09(R2014) |
≦0.25% |
Manufacturing direction:-0.046%
Across-manufacturing direction:-0.009% |
Seam strength |
EN 684:1995 |
N/A |
Ave.:360N/50mm Pass
Min.:330N/50mm |
Residual indentation
(%) |
ASTM F1700-13a &
ASTM F1914-07(2011) |
Average value≦8
Individual value≦10 |
0.4 Pass |
Resistance to chemicals |
ASTM F1700-13a &
ASTM F925-13 |
No more than a slight change in surface dulling,surface attack,or staining |
No change in surface dulling,surface attack,or staining was detected |
Heat stability |
ASTM F1514-03(R2013) |
△E*ab< 8 |
△E*ab=0.67 Pass |
Static loading |
ASTM F970-17 |
N/A |
0.04mm Pass |
Soluble heavy metal contents test |
ASTM F963-16(Clause 8.3) |
N/A |
Free |
Large ball impact resistance |
NALFA/ANSI LF-01-2011 |
N/A |
No cracks or fractures occurred at the height of 2500mm |
Static Electrical Propensity |
EN 1815:2016 method A |
≦2kV |
0.2kV |
Sound Transmission Class |
ASTM E90-2009(R2016)
ASTM E413-10 |
N/A |
STC=68 |
Formaldehyde |
ISO 17226-1:2008 |
N/A |
Free |
Surface Bond |
NALFA/ANSI LF-01-2011 |
N/A |
1.14MPa Pass |
Resilient floor covering Determination of peel resistance |
EN ISO 24345:2012 |
≥54N/50mm |
Longitudinal direction:95N/50mm
Cross direction:95N/50mm |
Castor chair Resistance(25000 Cycles) |
NALFA/ANSI LF-01-2011
ISO4918:2016 |
N/A |
No damage was found after test |
Thermal conductivity |
EN 12667:2001 |
N/A |
0.154 W/(m.K) |
Thermal Resistance |
EN 12667:2001 |
N/A |
0.033(m2.K)/W |
Colour Fastness |
EN ISO 105-B02:2014 |
N/A |
Grade 6 |
Curling |
ISO 23999:2008 |
N/A |
Average: 0.5mm Pass |
Locking strength |
ISO 10582:2017 Annex D |
Class 32,
type I:≥1.5kN/m |
Long side(X): 7.6 kN/m
Short side(Y): 6.3 kN/m Pass |
Resistance to staining |
ISO 26987:2008 |
N/A |
Index 0: Not affected Pass |
Slip resistance
(oil-wet ramp test) |
DIN 51130:2014-02 |
N/A |
Critical angle of inclination: 14.8°Classification: R10 Pass |
Resistance to bacteria |
ISO 846-1997 Method C |
N/A |
Assessment of bacteria growth: 0 Pass |
Scratch Resistance |
EN 16094B |
>2,500g |
3,500g |